Utility PV Solution

Built on Stability. Driven by Returns. Redefining Utility PV Excellence.
Watch the Video
Ultimate LCOE | Safe & Reliable | Optimized O&M

Utility PV Solution

Sigenergy’s utility solution is designed to maximize project value across diverse site and grid conditions. Focused on LCOE optimization, system reliability, and intelligent O&M, it enables stable operation, lower system costs, and stronger long-term returns across the entire project lifecycle.

Ultimate LCOE

Driven by a system-level design objective, Sigen PV Inverters are designed to break through traditional inverter power limits while enabling system-level AC and DC voltage upgrades.
By combining a true string inverter architecture with an advanced multi-MPPT design, the solution addresses PV string mismatch challenges. The design unlocks higher energy yield and significantly reduces the initial capital cost of utility-scale PV systems.
  • V
    AC Output Voltage
  • V
    Max. DC Input Voltage
  • kW+
    Max. Output Power
  • 1650 V
    Max. DC Input Voltage
  • 500 kW+
    Max. Output Power
    1000 V
    AC Output Voltage
  • 1650 V
    Max. DC Input Voltage
    Leading Long-String Design
    • 32
      Strings per inverter
    • 28
      PV modules per string
    Leading Long-String Design
    • 30
      PV modules per string
    • 5.09%
      Reduction in DC
      cable usage
    • 32
      Strings per inverter
    *The BOS is measured in specific scenarios
    Short-String
    Long-String
  • 500 kW+
    Max. Output Power
    1000 V
    AC Output Voltage
    Leading Large-Block Design

    Comparing with the block using 300 kW+ inverters
    Equipments reduced by 36% and AC-side cabling reduced by 35%

    Leading Large-Block Design
    With larger block architecture, BOS costs are further reduced.
    For a 100 MW plant, a 5 MW+ block can reduce BOS by 47.9% compared with a 3 MW+ block configuration.*
    *The BOS is measured in specific scenarios
    3.22MW Standard Block
    5.56MW Standard Block

True-string Inverter with Multi-MPPT Design

18
Sigen PV 500H1 MPPTs
2
PV Strings per MPPT

Multi-MPPT Design, Adapt to Various Application Scenarios

Mountain PV
~1.5%*
Higher Yield
Withstand
Inter-row shading
Withstand
Edge shading
Withstand
Mismatched orientation
8:00
12:00
18:00
Withstand
Inter-row shading
Withstand
Edge shading
Withstand
Mismatched orientation
*The data is based on controlled simulation conditions. Actual results may vary due to differences in products, software versions, usage conditions, and environmental factors. Please refer to actual conditions.

Upgraded Core Architecture

  • Innovative SiC Applications
    Developed with leading power device manufacturers, the design optimizes module layout and thermal management.Compared with conventional Si modules,junction temperature is reduced by 5-10°C, while voltage capability reaches 2000 V+.
  • Advanced Thermal Control
    Directed airflow, Eliminating internal airflow interference Zigzag heat exchange, lower chamber temperature

Safe & Reliable

Comprehensive DC-side fault monitoring and protection build a multi-layer active safety system. With rapid detection and response, electrical fault risks are minimized to enhance overall plant safety and reliability.
Designed for extreme environments including outside, salt spray, and sandstorms, the system delivers superior environmental resilience and stable performance, ensuring long-term reliable operation of large-scale solar plants.
Establishing an end-to-end security protection system

Complete Coverage of DC-side Faults

  • Utility-level AFCI*
  • Reverse Polarity Protection
  • PV Terminal Temperature Detection
The system features a fault detection range extending up to 500 m, capable of covering both long and short string configurations to accommodate photovoltaic power station designs of varying scales. Upon detecting an arc fault, the system rapid identification and disconnection, effectively suppressing sustained arc combustion and mitigating fire hazards.
* AFCI is optional
The system employs a two-string for per MPPT architecture design. In the event of abnormal wiring conditions such as reverse connection within a string, the limited circuit current results in a smaller fault current, thereby minimising the risk of significant current surges or sustained arcing. This design reduces electrical and thermal hazards under abnormal operating conditions, enhancing the system's operational safety and reliability.
The AC/DC terminals are fixed on board, enhancing temperature sampling accuracy and enabling sensitive detection of early-stage temperature rises. The system implements three-stage graded protection based on temperature rise thresholds and rate-of-change criteria, preventing unnecessary shutdowns while ensuring safety and improving power plant availability.
Built to Dominate All Environments

Higher Reliability

  • IP66
    Dual-compartment design with superior dustproof and waterproof capabilities, ensuring stable operation in complex and harsh outdoor environments such as wind, sand, rain and snow.
  • C5-H*
    Anti-corrosion coating treatment ensures long-term structural stability and reliability in demanding corrosive environments such as high salt spray and high humidity.
    * C5-H is optional
  • Type I+II*
    DC-side Type I+II lightning protection capability, capable of withstanding direct lightning strikes or intense lightning surge impacts, effectively enhancing equipment operational safety in thunderstorm environments.
    * Type I+II is optional

Optimized O&M

Designed with a lifecycle-focused O&M approach, Sigen PV Inverters provide end-to-end
coverage of the O&M workflow. Through system-level visibility and intelligent management,
the solution supports efficient and refined operation and maintenance of utility-scale PV
systems over their full lifecycle.

Effortless O&M Starts Here

1
Challenge 1
Numerous Devices, Slow Positioning
Geo-tagging
A positioning map is available in the mySigen App with registered inverter details, enabling rapid localization of inverters.Accurate positioning, avoid unnecessary detours.
2
Challenge 2
Difficulties in Fault Rectification
MPPT-level ISO Fault Positioning
Multi-MPPT design for enhanced fault location accuracy; insulation faults require inspection of only two strings.Rapid detection, accelerating fault rectification by 15 times.
3
Challenge 3
O&M Management Often Proves Difficult
Check-in Inspections
mySigen App integrates proximity check-in functionality, enabling in-range verification within 3-5 metres of inverters to enhance personnel assessment management efficiency.
1
Contact Us