The system features a fault detection range extending up to 500 m, capable of covering both long and short string configurations to accommodate photovoltaic power station designs of varying scales. Upon detecting an arc fault, the system rapid identification and disconnection, effectively suppressing sustained arc combustion and mitigating fire hazards.
* AFCI is optional
The system employs a two-string for per MPPT architecture design. In the event of abnormal wiring conditions such as reverse connection within a string, the limited circuit current results in a smaller fault current, thereby minimising the risk of significant current surges or sustained arcing. This design reduces electrical and thermal hazards under abnormal operating conditions, enhancing the system's operational safety and reliability.
The AC/DC terminals are fixed on board, enhancing temperature sampling accuracy and enabling sensitive detection of early-stage temperature rises. The system implements three-stage graded protection based on temperature rise thresholds and rate-of-change criteria, preventing unnecessary shutdowns while ensuring safety and improving power plant availability.